Sample building check
Sample: a 24 unit walk up, Toronto
An invented building, to show what your report carries. It is not a real client's building, and the findings are made up.
- Now4 findings
- Soon7 findings
- Plan2 findings
Common areas
Entrances, halls and stairs, exits, laundry, the boiler room and the outside walls
-
Now
Rear exit stairwell, ground floor
The emergency light did not come on when tested.
-
Now
Basement laundry
The vent duct behind dryer 2 is crushed, with lint built up behind the machine.
-
Soon
Boiler room
No service tag on the boiler dated in the last 12 months.
-
Soon
Front entrance
The closer slams the door, and the latch misses the strike about one time in three.
-
Soon
North corner, outside
The downspout empties against the foundation wall, and the soil there has washed out.
-
Plan
Second and third floor halls
Carpet worn through at both stair landings, and scuffed walls along both halls.
Unit 2
One bedroom, ground floor
-
Now
Kitchen sink
The slip joint on the trap has cracked, and water drips onto the cabinet floor. The subfloor is dry.
Seen 10:42 am
Seen 10:43 amKitchen sink, unit 2. In your report every finding carries its photos, each with its time; the sample shows one pair.
Doors, windows, appliances and the bathroom checked. Nothing else found.
Unit 5
Two bedroom, ground floor
-
Soon
Bathroom
The exhaust fan does not run. Mould spotting on the ceiling above the shower.
Unit 9
One bedroom, second floor
-
Now
Hallway
The smoke alarm did not sound when tested.
-
Plan
Kitchen
Cabinet doors sag on worn hinges, and the counter edge is chipped by the sink.
Unit 14
Two bedroom, second floor
-
Soon
Kitchen counter outlet
The outlet is loose in its box, and the cover plate is cracked.
-
Soon
Bedroom window
A broken balance: the sash will not stay up. The screen is torn.
Unit 21
Two bedroom, top floor
-
Soon
Bedroom closet ceiling
A water stain about the size of a hand, dry when checked.
Doors, windows, appliances and the bathroom checked. Nothing else found.
Priced list
The work for every finding, in priority order.
| Work | Where | Priority | Price |
|---|---|---|---|
| Replace the battery pack, or the fixture if it is worn out, then test it again. | Common areas, rear exit stairwell, ground floor | Now | Priced in your report |
| Replace the duct with a rigid metal run, clear the lint and check the outside hood opens. | Common areas, basement laundry | Now | Priced in your report |
| Replace the trap and its washers, dry the cabinet and check for leaks. | Unit 2, kitchen sink | Now | Priced in your report |
| Replace the alarm and test it. | Unit 9, hallway | Now | Priced in your report |
| Book a service by a TSSA registered contractor before the coldest weeks. | Common areas, boiler room | Soon | Priced in your report |
| Adjust or replace the closer and realign the strike plate. | Common areas, front entrance | Soon | Priced in your report |
| Add an extension to carry the water away from the wall, and regrade the bed. | Common areas, north corner, outside | Soon | Priced in your report |
| Replace the fan, clean and treat the ceiling, then repaint it with a bathroom paint. | Unit 5, bathroom | Soon | Priced in your report |
| Secure the outlet and replace the plate, by a licensed electrical contractor. | Unit 14, kitchen counter outlet | Soon | Priced in your report |
| Replace the balance and the screen. | Unit 14, bedroom window | Soon | Priced in your report |
| Check the roof above it before winter, and watch the stain for growth. | Unit 21, bedroom closet ceiling | Soon | Priced in your report |
| Budget for carpet at the landings and a repaint of both halls. | Common areas, second and third floor halls | Plan | Priced in your report |
| Budget for new hinges and a counter edge repair at the next turnover. | Unit 9, kitchen | Plan | Priced in your report |
In your report every line carries a price, before HST. Nothing goes ahead until you approve it, and approved work is billed as a normal job.
Licensed work goes to licensed trades: gas to TSSA registered contractors, pest control to licensed exterminators. We only use ECRA/ESA-Licensed Electrical Contractors.